Guide

How to calculate stair stringers

A worked method from total rise to stringer length. State your code limits before you cut.

Rise & Run

There is no universal "always N risers." Riser count depends on total rise and the maximum riser your code allows.

Method

  1. Measure total rise (H). Finished upper walking surface straight down to finished lower landing.
  2. Choose riser count. Start near ceil(H / Rmax) and compare a few equal-riser options under your max limit.
  3. Equal risers. Unit riser R = H / n. Tread count for a common deck-to-pad layout is n − 1 when the top finish is the deck.
  4. Set tread depth (T). From your code minimum or a chosen depth at or above it.
  5. Run and stringer length. Run = treads × T. Stringer length along the pitch is √(H² + Run²).
  6. First riser cut. Shorten the first stringer riser by tread thickness so finished steps stay equal. See first riser boost.
  7. Throat and board. After the notch, check remaining throat before you commit to 2x10 or 2x12. See throat boost.

Planning math only. Confirm adopted code, stringer spacing, connectors, and footing details with your inspector and structural assumptions before you build.

Live calc: join the iOS waitlist. Quick measure step: deck rise checklist.